Home Company profile Testing Laboratory

Testing Laboratory

Testing LaboratoryERKON has a great Testing Laboratory, where the tests of all products are regularly carried out. Testing Center performs in accordance with the accepted worldwide standard ISO / IEC 17025 (General requirements for the competence of testing and calibration laboratories / centers).

All tests are carried out in accordance with the international standards IEC 60115-1 and IEC 60068-2-xx.

All tests are aimed to confirm the stability and reliability of our products.

The main tests include:

  • Endurance (Load Life)

  • Solderability
  • Resistance to Soldering Heat

    Climatic testing:
  • Rapid Change of Temperature
  • Damp heat with load

    Mechanical testing:
  • Robustness of Termination (Bending, Tensile)
  • Vibration

The testing laboratory also makes it possible to conduct many other tests, including: short time overload, single- and periodic pulse high-voltage overload, insulation resistance, component solvent resistance, low air pressure and others.

Endurance (Load Life):

  • Test chamber model Z
    Versatile test chamber for resistors and inductors. Provides continuous testing of products under electric load during no less than 1000 hours.
    • Air Temperature in chamber’s storage capacity from +70 до +155 ˚С.
    • The limits of voltage output from 0 to 800 V.
    • Temperature deviation in chamber’s storage capacity from specified values: ±3 ˚С.
  • Test chamber model T
    Test chamber for power resistors (R1-120, R1-121, R1-130, PR1-21, PR1-23, R1-134, R2-108).
    • Air Temperature in chamber’s storage capacity from +45 до +125 ˚С.
    • Temperature deviation in chamber’s storage capacity from specified values : ±3 ˚С.   

Testing LaboratoryClimatic tests:

  • Climatic chamber model 12KT
    Climatic test chamber.
    • Provides automatic obtaining and maintenance of temperatures from +50 to +350 ˚С.
    • Temperature deviation at any point of storage capacity from specified values: ±2˚ С.
  • Climatic chamber model  KTV-240
    Climatic chamber for damp heat with load.
    • Provides automatic obtaining and maintenance of temperatures from +25 to +155 ˚С.
    • Temperature deviation at any point of storage capacity from specified values:  ±2˚ С.
    • Provides maintenance and registration of the relative humidity of the environment up to 98% with accuracy from -3 to +2 %.    

Mechanical testing (Vibration):

  • Vibrating stand model UVE-1
    • Test unit for vibration test.
    • Navigation mode in the range 10 ÷ 70 Hz. Maximum navigation value – 5 mm.
    • The acceleration mode in the frequency range 40 ÷ 5000 Hz. Maximum acceleration mode – 45 g (450 m/s2).
    • Maximum allowable weight of device (holder) – 1 kg. Multiple automatic frequency trace is provided in the range  of 10 ÷ 5000 Hz with a speed of 0,2 ÷ 10,0 oct/min.
    • The allowable tolerance limits of acceleration and movement representation at the reference point doesn’t exceed  ±15%.